Failed Miserably!

We failed the electrical inspection! Sad to say the inspector was not happy with so many things he requested a meeting with the contractor that will happen in a couple of days. So I had a feeling about those workers! With such a particular job it would have been good to have the best they have. So we will revisit the installation.

None of this wiring in the ceiling will pass. It must be back 1 1/4″ from the surface or in conduit.

Wiring in Ceiling

Wiring in Ceiling

Several of the mid wall holes are not centered so need metal plates. The wiring in my 2 x 2 wall is stapled too close to the surface too.

The small lengths of wire mold that were installed for the track lights do not have end caps that the inspector said they need.

The corner where the fireplace will be enclosed is not built so the inspector can’t pass it for inspection as it is. Again the wire would need to be in conduit.

I guess I am not actually upset about this delay. We have taken this long to complete the project for sure. It is just that I think the workers didn’t care about this project and did sloppy work wanting to argue with me instead of find solutions. That was the hard part for me. I care so much about it that having someone else come in and assume the system is wrong because they have not seen it before is depressing.

I think I’ll request a different crew for the fixes. One last day a new guy showed up and wired the wood boiler electrical box and the work just appears so much neater. Maybe I’ll ask for him.